HOBOnet Water Level Sensor Interface
Eine drahtlose Sensorschnittstelle, die mit dem HOBOnet-System zur Fernüberwachung des Wasserstands arbeitet.
Wichtige Informationen
Ein vollständiges System erfordert mindestens einen HOBOnet Wasserstandssensor, a Direktlesekabel, und eine HOBO RX3000 Fernüberwachungsstation und HOBOnet Drahtlos-Manager (oder ein HOBO MicroRX-Station mit einem integrierten HOBOnet Wireless Manager). HOBOnet Wireless Repeater (RXW-RPTR-xxx oder RXW-RPTR-B-xxx) können hinzugefügt werden, um die Reichweite zu erhöhen.
- 10 für jeweils CHF 363.75 kaufen und 3% sparen
- 25 für jeweils CHF 356.25 kaufen und 5% sparen
- 50 für jeweils CHF 345.00 kaufen und 8% sparen
- 100 für jeweils CHF 330.00 kaufen und 12% sparen
Overview
The HOBOnet water level sensor interface features a pre-configured, easily deployed wireless sensor that communicates accurate, reliable water level data directly to a HOBO RX3000 or HOBO MicroRX station, the core component of the HOBOnet remote monitoring system.
HOBOnet is a cost-effective, scalable, user-friendly wireless sensor network that lets you streamline data retrieval by effortlessly monitoring multiple wells with a single cellular device. Data is accessed from anywhere, at any time, through the customizable dashboard in HOBOlink, Onset's innovative cloud software platform – eliminating the need for frequent site visits that are both time-consuming and costly. HOBOlink also sends automatic, real-time text/email notifications to alert you of any sensor or system alarms, providing the insights you need to make informed decisions, react quickly to stay ahead of issues, and ensure compliance.
Other key benefits:
- User-friendly setup process
- A proven water level sensor for accurate, reliable readings
- Rechargeable batteries and built-in solar panel eliminate downtime
- Real-time insights via customized dashboards in HOBOlink, leaving delays in the past
- No data loss due to user error, with temperature-compensated pressure readings for accurate, reliable information
- HOBOlink cloud dashboards for in-depth data analysis and smarter decision-making
- Kevlar-reinforced cable with integrated strain relief mechanism
Features
Sensor Features
- Non-vented design reduces maintenance
- Durable, ceramic sensor can withstand freezing
- 3-point NIST-traceable calibration certificate
Wireless Features
- Sub-GHz wireless mesh self-healing technology for expansive coverage
- 450 to 600 meter (1,500 to 2,000 feet) wireless range and up to five hops
- Up to 50 wireless sensors or 336 data channels per one HOBO RX station
- Simple button-push to join the HOBOnet wireless network
- Onboard memory to ensure no data loss
- Powered by rechargeable AA batteries and built-in solar panel
Specifications
Wireless Mote
- Operating Temperature Range
-
-25° to 60°C (-13° to 140°F) with rechargeable batteries-40° to 70°C (-40° to 158°F) with lithium batteries
- Radio Power
-
12.6 mW (+11 dBm) non-adjustable
- Transmission Range
-
Reliable connection to 457.2 m (1,500 ft.) line of sight at 1.8 m (6 ft.) highReliable connection to 609.6 m (2,000 ft.) line of sight at 3 m (10 ft.) high
- Wireless Data Standard
-
IEEE 802.15.4
- Radio Operating Frequencies
-
RXW-WL-900: 904–924 MHzRXW-WL-868: 866.5 MHzRXW-WL-921: 921 MHzRXW-WL-922: 916–924 MHz
- Modulation Employed
-
OQPSK (Offset Quadrature Phase Shift Keying)
- Data Rate
-
Up to 250 kbps, non-adjustable
- Duty Cycle
-
<1%
- Maximum Number of Motes
-
Up to 50 wireless sensors or 336 data channels per one HOBO RX station
- Logging Rate
-
1 minute to 18 hours
- Number of Data Channels
-
4 (Water Level, Differential Pressure, Water Temperature, Barometric Pressure)
- Battery Type / Power Source
-
Two AA 1.2V rechargeable NiMH batteries, powered by built-in solar panel or two AA 1.5 V non-rechargeable lithium batteries for operating conditions of -40 to 70°C (-40 to 158°F)
- Battery Life
-
With NiMH batteries: Typical 3–5 years when operated in the temperature range -20° to 40°C (-4°F to 104°F) and positioned toward the sun, operation outside this range will reduce the battery service life.With non-rechargeable lithium batteries: 1 year, typical use
- Memory
-
16 MB
- Dimensions
-
Interface Connector Diameter: 25.4 mm (1 inch)Cable length: 1.83 m (6 ft)Mote: 16.2 x 8.59 x 4.14 cm (6.38 x 3.38 x 1.63 inches)
- Weight
-
229 g (8.08 oz)
- Materials
-
Sensor: Polycarbonate housing encasing epoxy sealed circuit boardCable: PolyurethaneMote: PCPBT, silicone rubber seal
- Environmental Rating
-
Mote: IP67, NEMA 6
Water Level Sensor
- See referenced below
-
* Water Level Accuracy: With accurate reference water level measurement, known water density, & a stable temp environment. System Water Level Accuracy equals the sum of the Barometric Water Level Accuracy plus the selected sensor end Water Level Accuracy.** Raw Pressure Accuracy: Absolute pressure sensor accuracy includes all sensor drift, temperature, and hysteresis-induced errors.***Changes in Temperature: Allow 20 minutes in water to achieve full temperature compensation of the pressure sensor. Can be up to 0.5% of additional error due to rapid temperature changes. Measurement accuracy also depends on temperature response time.
Pressure (Absolute) and Water Level Measurements MX2001-01-SS-S and MX2001-01-Ti-S
- Operation Range
-
0 to 207 kPa (0 to 30 psia); approximately 0 to 9 m (0 to 30 ft) of water depth at sea level, or 0 to 12 m (0 to 40 ft) of water at 3,000 m (10,000 ft) of altitude
- Factory Calibrated Range
-
69 to 207 kPa (10 to 30 psia), 0° to 40°C (32° to 104°F)
- Burst Pressure
-
310 kPa (45 psia) or 18 m (60 ft) depth
- Water Level Accuracy*
-
Typical error: ±0.05% FS, 0.5 cm (0.015 ft) waterMaximum error: ±0.1% FS, 1.0 cm (0.03 ft) water
- Raw Pressure Accuracy**
-
±0.3% FS, 0.62 kPa (0.09 psi) maximum error
- Resolution
-
<0.02 kPa (0.003 psi), 0.21 cm (0.007 ft) water
- Pressure Response Time (90%)***
-
<1 second at a stable temperature
Pressure (Absolute) and Water Level Measurements MX2001-02-SS-S
- Operation Range
-
0 to 400 kPa (0 to 58 psia); approximately 0 to 30.6 m (0 to 100 ft) of water depth at sea level, or 0 to 33.6 m (0 to 111 ft) of water at 3,000 m (10,000 ft) of altitude
- Factory Calibrated Range
-
69 to 400 kPa (10 to 58 psia), 0° to 40°C (32° to 104°F)
- Burst Pressure
-
500 kPa (72.5 psia) or 40.8 m (134 ft) depth
- Water Level Accuracy*
-
Typical error: ±0.05% FS, 1.5 cm (0.05 ft) waterMaximum error: ±0.1% FS, 3.0 cm (0.1 ft) water
- Raw Pressure Accuracy**
-
±0.3% FS, 1.20 kPa (0.17 psi) maximum error
- Resolution
-
<0.04 kPa (0.006 psi), 0.41 cm (0.013 ft) water
- Pressure Response Time (90%)***
-
<1 second at a stable temperature
Pressure (Absolute) and Water Level Measurements MX2001-03-SS-S
- Operation Range
-
0 to 850 kPa (0 to 123.3 psia); approximately 0 to 76.5 m (0 to 251 ft) of water depth at sea level, or 0 to 79.5 m (0 to 262 ft) of water at 3,000 m (10,000 ft) of altitude
- Factory Calibrated Range
-
69 to 850 kPa (10 to 123.3 psia), 0° to 40°C (32° to 104°F)
- Burst Pressure
-
1,200 kPa (174 psia) or 112 m (368 ft) depth
- Water Level Accuracy*
-
Typical error: ±0.05% FS, 3.8 cm (0.125 ft) waterMaximum error: ±0.1% FS, 7.6 cm (0.25 ft) water
- Raw Pressure Accuracy**
-
±0.3% FS, 2.55 kPa (0.37 psi) maximum error
- Resolution
-
<0.085 kPa (0.012 psi), 0.87 cm (0.028 ft) water
- Pressure Response Time (90%)***
-
<1 second at a stable temperature
Pressure (Absolute) and Water Level Measurements MX2001-04-SS-S and MX2001-04-Ti-S
- Operation Range
-
0 to 145 kPa (0 to 21 psia); approximately 0 to 4 m (0 to 13 ft) of water depth at sea level, or 0 to 7 m (0 to 23 ft) of water at 3,000 m (10,000 ft) of altitude
- Factory Calibrated Range
-
69 to 145 kPa (10 to 21 psia), 0° to 40°C (32° to 104°F)
- Burst Pressure
-
310 kPa (45 psia) or 18 m (60 ft) depth
- Water Level Accuracy*
-
Typical error: ±0.075% FS, 0.3 cm (0.01 ft) waterMaximum error: ±0.15% FS, 0.6 cm (0.02 ft) water
- Raw Pressure Accuracy**
-
±0.3% FS, 0.43 kPa (0.063 psi) maximum error
- Resolution
-
<0.014 kPa (0.002 psi), 0.14 cm (0.005 ft) water
- Pressure Response Time (90%)***
-
<1 second at a stable temperature
Barometric Pressure (RXW-WL-xxx)
- Operation Range
-
66 to 107 kPa (9.57 to 15.52 psia)
- Temperature Calibrated Range
-
-20 to 50°C (-4 to 122°F)
- Accuracy
-
±0.2 kPa (±0.029 psi) over full temperature range at fixed pressure; maximum error ±0.5% FS
- Water Level Accuracy*
-
Typical error: ±0.075% FS, 0.3 cm (0.01 ft) waterMaximum error: ±0.15% FS, 0.6 cm (0.02 ft) water
- Resolution
-
<0.01 kPa (0.0015 psi)
- Response Time
-
<1 second at stable temperature
- Stability (Drift)
-
<0.01 kPa (0.0015 psi) per year
Temperature Measurements (All Sensor End Models MX2001-0x-SS-S and MX2001-0x-Ti-S)
- Operation Range
-
-20° to 50°C (-4° to 122°F)
- Accuracy
-
±0.44°C from 0° to 50°C (±0.79°F from 32° to 122°F)
- Resolution
-
0.1°C at 25°C (0.18°F at 77°F)
- Response Time (90%)
-
5 minutes in water (typical)
- Stability (Drift)
-
0.1°C (0.18°F) per year