HOBO 30-Foot Depth Water Level Data Logger
Records water level and temperature up to 30-ft depths with no cumbersome vent tubes or desiccants to maintain.
Available in stainless-steel for shallow wells, streams, lakes, and freshwater wetlands and in titanium for saltwater/brackish wetlands and tidal areas.
Important Information
Requires HOBOware Pro software and either a U-DTW-1 Waterproof Shuttle or the Base-U-4 Optic USB Base Station for configuration and data offload. Please see compatible items below.
CHF 749.00
SKU
U20-001-01
- Buy 10 for CHF 726.55 each and save 3%
- Buy 25 for CHF 711.55 each and save 5%
- Buy 50 for CHF 689.10 each and save 8%
- Buy 100 for CHF 659.15 each and save 12%
Overview
Featuring high accuracy at a great price and ease-of-use, with no cumbersome vent tubes or desiccants to maintain, this logger is ideal for recording water level and temperature up to 30-ft depths in shallow wells, streams, lakes, freshwater wetlands (stainless-steel), saltwater/brackish wetlands and tidal areas (titanium).
Features
- Lightning protection - no long signal wires, and electronics are shielded in a metal housing
- HOBOware Pro software provides easy conversion to accurate water level reading, fully compensated for barometric pressure, temperature, and water density
- Multiple-rate sampling allows faster sampling at critical times such as when pumping starts or stops
- Available in four depth ranges
- Ideal for use in wells, streams, lakes, wetlands, and tidal areas
- No-vent-tube design for easy, reliable deployment
- Available in stainless and titanium versions
- Durable ceramic pressure sensor
- 3-point NIST-traceable calibration certificate included
What's in the box
- HOBO U20-001-01 or U20-001-01-Ti Water Level Data Logger (30-foot depth)
Specifications
Pressure and Water Level Measurements U20-001-01 and U20-001-01-Ti
- Operation Range
-
0 to 207 kPa (0 to 30 psia); approximately 0 to 9 m (0 to 30 ft) of water depth at sea level, or 0 to 12 m (0 to 40 ft) of water at 3,000 m (10,000 ft) of altitude
- Factory Calibrated Range
-
69 to 207 kPa (10 to 30 psia), 0° to 40°C (32° to 104°F)
- Burst Pressure
-
310 kPa (45 psia) or 18 m (60 ft) depth
- Water Level Accuracy*
-
Typical error: ±0.05% FS, 0.5 cm (0.015 ft) waterMaximum error: ±0.1% FS, 1.0 cm (0.03 ft) water
- Raw Pressure Accuracy**
-
±0.3% FS, 0.62 kPa (0.09 psi) maximum error
- Resolution
-
<0.02 kPa (0.003 psi), 0.21 cm (0.007 ft) water
- Pressure Response Time (90%)***
-
<1 second; measurement accuracy also depends on temperature response time
Temperature Measurements (All Models)
- Operation Range
-
-20° to 50°C-4° to 122°F
- Accuracy
-
±0.44°C from 0° to 50°C (±0.79°F from 32° to 122°F), see Plot A in manual
- Resolution
-
0.10°C at 25°C (0.18°F at 77°F), see Plot A in manual
- Response Time (90%)
-
5 minutes in water (typical)
- Stability (Drift)
-
0.1°C (0.18°F) per year
Logger
- Real-time Clock
-
± 1 minute per month 0° to 50°C32° to 122°F
- Battery
-
2/3 AA, 3.6 Volt lithium, factory-replaceable
- Battery Life (Typical Use)
-
5 years with 1 minute or greater logging interval
- Memory (Non-volatile)
-
64K bytes memory (approx. 21,700 pressure and temperature samples)
- Weight
-
Stainless steel models: approximately 210 g (7.4 oz)Titanium models: approximately 140 g (4.8 oz)
- Dimensions
-
2.46 cm (0.97 inches) diameter, 15 cm (5.9 inches) length; mounting hole 6.3 mm (0.25 inches) diameter
- Wetted Materials
-
316 stainless steel, Viton® o-rings, acetyl cap, ceramic sensor
- Logging Interval
-
Fixed-rate or multiple logging intervals, with up to 8 user-defined logging intervals and durations; logging intervals from 1 second to 18 hours. Refer to the HOBOware software manual.
- Launch Modes
-
Immediate start and delayed start
- Offload Modes
-
Offload while logging; stop and offload
- Battery Indication
-
Battery voltage can be viewed in status screen and optionally logged in datafile. Low battery indication in datafile.
- Environmental Rating
-
IP68
-
* Water Level Accuracy: With accurate reference water level measurement, known water density, accurate Barometric Compensation Assistant data, and a stable temperature environment.** Raw Pressure Accuracy: Absolute pressure sensor accuracy includes all sensor drift, temperature, and hysteresis-induced errors.*** Changes in Temperature: Allow 10 minutes in water to achieve full temperature compensation of the pressure sensor. Maximum error due to rapid thermal changes is approximately 0.5%.
![CE Compliance Mark](/images/ce-mark.png)
Documentation
HOBOware Pro Barometric Compensation Assistant - User’s Guide
EnglishHOBO U20 Water Level Logger (U20-001-0x and U20-001-0x-Ti) User's Manual
EnglishGerman
Sample U20 Calibration Certificate
EnglishU20 Water Level Loggers Data Sheet
EnglishHOBO® U20 Water Level (U20-001-0x and U20-001-0x-Ti) Logger Quick Start
EnglishHOBO TL 5955 Battery MSDS
EnglishAccessory
Carrying Case
Data Offload - Base Stations - Shuttles - Couplers
Protective Enclosures
Stainless Steel Cable/Crimps
Well Caps
Compliance Certificates
Required Communications
Data Offload - Base Stations - Shuttles - Couplers